HI8730,HI8731和HI8732系列測定儀,可同時測定電導率、總?cè)芙夤腆w和溫度,操作簡單,便于維護。采用單點校準,測值準確,HI761285電極內(nèi)置溫度傳感器,具有自動溫度補償功能。適用于多種領(lǐng)域的現(xiàn)場測定。*自動溫度補償*電極內(nèi)置溫度傳感器且便于維護根據(jù)測量范圍選擇的具體型號:HI8730:電導率0to1990 S/cm,總?cè)芙夤腆w0to1990ppm,溫度0to70 CHI8731:電導率0to6000 S/cm,總?cè)芙夤腆w0to3000ppm,溫度0to70 CHI8732:電導率0to4.00mS/cm,總?cè)芙夤腆w0to1999ppm,溫度0to70 C測量類別測量項目HI8730HI8731HI8732測量范圍電導率-EC0to1999 S/cm0to6000 S/cm0.00to4.00mS/cm總固體溶解度-TDS0to1990ppm(mg/L)0to3000ppm(mg/L)0to1999ppm(mg/L)溫度?C0.0to70.0 C解析度電導率-EC10 S/cm10 S/cm0.01mS/cm總固體溶解度-TDS10ppm(mg/L)10ppm(mg/L)1ppm(mg/L)溫度?C1 C0.1 C0.1 C測量精度電導率-EC 2%F.S總固體溶解度-TDS 2%F.S溫度?C 1 C 0.5 C溫度補償轉(zhuǎn)換因子溫度補償-EC/TDS自動溫度補償0to50 C(32to122 F),補償系數(shù) =2%/ CTDS轉(zhuǎn)換因子0.50.56to0.72可調(diào)校準模式EC/TDS校準手動單點校準溫度校準出廠校準電極類型HI761285DIN接口EC/TDS專用電極電源模式1x9V電池使用環(huán)境0to50 C(32to122 F) Max.RH100%(無冷凝)尺寸重量主機:164x76x45mm;主機重量:205g 訂貨型號標準配置描述HI8730HI8730主機、HI761285DIN接口EC/TDS專用電極、緩沖液、攜帶箱、中英文資料HI8731HI8731主機、HI761285DIN接口EC/TDS專用電極、緩沖液、攜帶箱、中英文資料HI8732HI8732主機、HI761285DIN接口EC/TDS專用電極、緩沖液、攜帶箱、中英文資料 附件類別選購型號基本功能描述電極類HI761285DIN接口EC/TDS專用電極電導率標準緩沖液HI7031L標準值:1413 S/cm,規(guī)格:500mL;電導率常規(guī)校準緩沖液HI7039L標準值:5000 S/cm,規(guī)格:500mL;電導率常規(guī)校準緩沖液總固體溶解度標準液HI7032L標準值:1382ppm,規(guī)格:500mL;總固體溶解度常規(guī)校準緩沖液HI70442L標準值:1500ppm,規(guī)格:500mL;總固體溶解度常規(guī)校準緩沖液電極清洗液HI7061L普通電極清洗液,規(guī)格:500mL其他附件HI710015橡膠防震專用保護套HI76404可調(diào)式電極支架HI710029A充電器暨一節(jié)可充9V電池HI740029高性能可充9V電池HI208424儀器專用攜帶箱